{"product_id":"004-0-0017-s8-alarm-5-co2-sensor","title":"004-0-0017 S8 Alarm 5% CO2 Sensor","description":"\u003cp\u003eThe \u003cstrong\u003eS8 5% Alarm CO2 Sensor (004-0-0017)\u003c\/strong\u003e is designed to act like a safety switch for alarm applications where CO2 leak detection around tanks or cylinders of compressed CO2 gas is required. It comes with Automatic Background Calibration (ABC) turned on.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003c\/em\u003eThanks to a new optical path design, the S8 can accurately measure carbon dioxide levels up to 5%, yet it has less than a 30x20x10mm footprint and runs on only 30mA.\u003c\/p\u003e\n\u003cp\u003eThis sensor is designed for commercial applications. It provides simple communication via UART which lets you change the measurement period and control the ABC period in real time. Background and zero-gas calibrations are also implemented in a simple manner.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLow Power, Small Footprint Design\u003c\/li\u003e\n\u003cli\u003eAutomatic Background Calibration\u003c\/li\u003e\n\u003cli\u003eIndustry-Standard UART Communication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eS8 Alarm 0-5% CO2 Sensor\u003c\/strong\u003e (004-0-0017) - pinless design for integration into high-volume OEM products. \u003cstrong\u003eABC on.\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCO2 Measurement\u003c\/strong\u003e: non-dispersive infrared (NDIR)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Method\u003c\/strong\u003e: Diffusion\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e: 0-5% (0-50,000ppm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse time\u003c\/strong\u003e: 90% at 2 minutes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRate of Measurement\u003c\/strong\u003e: \u003cspan\u003e 0.5 Hz (every 2 seconds)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy\u003c\/strong\u003e: ± 200ppm ± 10% of measured value\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAvailable Output\u003c\/strong\u003e: analog\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Options\u003c\/strong\u003e: UART Modbus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Life Expectancy\u003c\/strong\u003e: \u0026gt; 15 years\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance Interval\u003c\/strong\u003e: no maintenance required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelf-Diagnostics\u003c\/strong\u003e: complete function check on startup\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \/ Mechanical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions\u003c\/strong\u003e: 32.7 × 19.7 × 8 mm (LxWxH)  \u0026lt; 8 grams.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input\u003c\/strong\u003e: 4.5-5.25 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Current\u003c\/strong\u003e: 300 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption\u003c\/strong\u003e: 300mA peak, 30mA average\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 days - See \u003cstrong\u003eCO2Meter Terms and Conditions.\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094=\u0026amp;width=700\" alt=\"CO2 Sensor Documention\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e S8 5% Datasheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094=\u0026amp;width=700\" alt=\"CO2 Sensor Documention\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e S8 5% Sensor Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094=\u0026amp;width=700\" alt=\"CO2 Sensor Documention\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003e Modbus Communication Manual (pdf)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094=\u0026amp;width=700\" alt=\"CO2 Sensor Documention\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Connecting to Raspberry Pi via UART (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif?width=700\" alt=\"\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Raspberry Pi Sample Code (ZIP)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094=\u0026amp;width=700\" alt=\"CO2 Sensor Documentation\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Connecting to TI CC3200 WIFI via UART (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093=\u0026amp;width=700\" alt=\"Senseair ISO Certification\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Senseair ISO Certification (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Senseair","offers":[{"title":"Default Title","offer_id":44091993063514,"sku":"qyc1789508644736","price":28.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0739\/0291\/5674\/files\/004-0-0017-s8-alarm-5-co2-sensor_1.jpg?v=1789508648","url":"https:\/\/paisleyoutfitstore.shop\/products\/004-0-0017-s8-alarm-5-co2-sensor","provider":"My Store","version":"1.0","type":"link"}